RF Measurement — Broadband noise source
NS-1
A known noise, to see the RF path.
The NS-1 is a 100 – 1500 MHz white noise generator, −75 dBm per 200 kHz, powered by the DC feed. In place of the antenna, it turns the receiver's scan into an analyzer of the RF path: cable loss, filtering, DC feed. 10 – 18 V, 57 × 25 × 18 mm, 20 g.
Bandwidth
100 – 1500 MHz
Level
−75 dBm / 200 kHz
Flatness
±0.5 dB (100 – 1000 MHz)
Power
DC feed 10 – 18 V
Connector
BNC male
Highlights
100 – 1500 MHz white noise
A white noise generator flat across the whole UHF band: −75 dBm per 200 kHz, within ±0.5 dB from 100 to 1000 MHz.
−75 dBm / 200 kHz · ±0.5 dB
Your receiver becomes an analyzer
In place of the antenna, the NS-1 injects a known noise; the receiver's scan then shows the actual bandwidth of the RF path, like an analyzer with a tracking generator.
NS-1 + scan = tracking generator
Powered by the DC feed
Screws onto the antenna input or the end of the cable and draws from the receiver's or splitter's DC feed. It checks on the way that the DC feed reaches the end.
10 – 18 V · 100 mA · BNC male
In detail
The NS-1 is a white noise generator in the 100 – 1500 MHz band, powered through the DC feed. It allows a quick test of an RF path: connected in place of the UHF antenna, it injects a known level, −75 dBm per 200 kHz, flat within ±0.5 dB from 100 to 1000 MHz.
A scan run on the receiver then shows the actual bandwidth of the path: NS-1 + scan act like a spectrum analyzer with a tracking generator.
You can thus check the RF loss of the path, the state of a coax cable, the coherence of a filter if there is one, and the DC feed itself, since the NS-1 only produces noise when powered.
10 – 18 V power through the DC feed, 100 mA. BNC male connector, to screw directly onto the antenna input or the end of the cable. 57 × 25 × 18 mm, 20 g.
Specifications
The numbers that matter.
Condensed excerpt. See the datasheet for detailed conditions.
RF
Power
Mechanical
Use cases
Cables
Measure a coax cable loss
Scan with the NS-1 on the receiver, then with the cable under test in between: the level difference is the cable loss. 10 m of RG223: about 3 dB.
Filters
Check a filter's coherence
With an FA-1 or a filtered splitter in the path, the scan draws the filter's band and gain: you see whether the chosen block covers the frequencies in use.
DC feed
Test the DC feed at the end of the line
The NS-1 only produces noise when powered: a flat scan at the expected level proves the DC feed reaches the end of the cable.